iBoot-PDU – North American Models

iBoot-PDU – North American Models

$0.00$630.00

Rev A Models :  1530142 1530142 1530141 1530144 1530143 1530182 15301081 1530184 1530183 1530186 1530185 1530187 Rev - Models : 1530042 1530042 1530041 1530044 1530043 1530082 1530081 1530084 1530083 1530086 1530085 1530087

Major Project Expertise

If you manage a network with hundreds or thousands of sites, every second of downtime costs you serious amounts of dollars. Our solutions are optimized to help you deploy and manage large scale installations around the world and keep them running with minimal downtime.

TOP FEATURES

Clear Status and Easy Control

Power Distribution Units with clear easy to use web interface. This rack mounted PDU makes it easy to manage A/C power from any location. This is a switched and managed PDU, each outlet is independently controlled.

The web page presents a clear status indication of each outlet, current draw across all inputs and the AutoPing monitoring, if implemented. Multiple PDUs can be managed from a single web page.

Each outlet on this PDU can be individually selected, or multiple outlets can be simultaneously operated. User selectable cycle timer allows single command reboot. Delay timer limits inrush current by staggering power up when multiple devices are simultaneously controlled.

TOP FEATURES

Simple Web Control

Clean web page design makes it easy to see the status and control power to any outlet. History log shows the last 5 events. Adaptive mobile pages make it easy to make that quick reboot from you smartphone while on the go.

10/100 Switch

Get the reboot you need without an unnecessary cable run to the wiring closet. With Model iBoot-G2S, the built-in 10/100 switch makes it easy to add the power of iBoot to your existing installation. Perfect for digial signage, kiosks and telemetry systems in those hard to reach areas. Putting the iBoot in-line between the router and the server makes it easy to test both and reboot automatically.

Free cloud service

iBoot Cloud Service (iBCS) allows customers with iBoot to access and control multiple iBoots in multiple locations from a single portal with a single sign-on.

Automatic Reboot

iBoot automatically monitors and protects your network. AutoPing continuously tests your connectivity to the internet or to any device on your network. When the network is down, or the device stops functioning, iBoot reboots the failed system to get you back on-line fast.

Expansion Outlets

iBoot-G2S and iBoot-G2+ are expandable with low cost satellite units to provide independent control of up to three outlets, with separate AutoPing monitoring as needed. If not used with the expansion units, the ports on the iBoot-G2S can be used as General Purpose I/O or as manual override control for the power outlets.

UL Listed for Safety

Dataprobe Remote Reboot products are UL Listed. This means they are tested by Underwriters Labratories and Certified to meet their exacting standards. It also means that the tests conducted are appropriate for the type of device under test. Only devices that are tested and pass all the tests conducted by UL can apply the UL label.

Pays for itself
with the first
service
call
saved

Don’t get in the car just to push that big red button. iBoot can automatically restart crashed systems or put the power of remote reboot in your hands, wherever you are.

How Much Can You Save?

Discover your true Cost of Downtime and how fast your ROI on iBoot will be.

Learn More about iBoot-PDU – North American Models

Features of iBoot-PDU – North American Models

Independently Controllable Outlets

The iBoot-PDU series is designed to provide power distribution and remote power control. Each iBoot-PDU allows four or eight outlets to be independently switched on and off for reboot, energy management and security. The iBoot-PDU has many features to make the management of power distribution simple and cost effective:

Web Browser Control

Simple web browser interface is easy to use and provides complete status information and control of the outlets, and groups.

Integrated 1Gig Ethernet Switch

Simplify network wiring and reduce home runs to the router. This two port passive switch makes it easy to add remote power management to existing installations.

Telnet/Serial CLI Control

Telnet and serial access use the same Command Line Interface (CLI) structure and syntax to completely configure the iBoot-PDU, or multiple iBoot-PDUs in a cluster configuration.

Multiple Users

Multiple users can be assigned administrator or user only rights, plus access to specific outlets and groups. Users only see the outlets and groups they are assigned to.

Grouping of Outlets for Simultaneous Management

Multiple outlets, across multiple iBoot-PDUs in clustered configurations can be linked together in named groups and managed together. This allows for example, power cycling all devices of a certain type together.

 

Multiple iBoot-PDU Cluster Configuration

Additional iBoot-PDUs can be managed from a single unit. One master iBoot-PDU provides the communication to the users and continuously receives status information from the rest of the iBoot-PDUs in the cluster. Groups can be created across multiple PDUs and controlled simultaneously.

Automation

The iBoot-PDU can monitor voltage, current and temperature to provide automatic response to the physical environment. AutoPing testing monitors network elements. Program complex sequences of outlet actions and notifications to respond instantly to out of normal situations. Temperature monitoring requires add-on probe.

Real-Time Event Control

Set automatic power actions based on your schedule. Restart systems every day to reduce memory bloat. Power up resources only when needed for energy management, lifecycle extension or security.

Landline Modem Option

The add-on landline modem supports data calls from terminal devices using the CLI, and direct dial from a tone telephone for simple on/off control when more sophisticated means are not available. Voice modem also allows phone dial tone control with voice response (Basic functions only)

Network Management

Setup and Control functions can be linked to any SNMP v2c compatible manager. The iBoot-PDU MIB is downloadable from the website. Reports to syslog server.